Posted on Leave a comment

Water Management System PCB Revisions

OK, a few revisions have been made to the water management PCB, mainly to reduce the possibility of the brushed DC motors in the water pumps from causing the MCU to crash, with the other changes to the I/O connector positioning & finally upgrading the reverse blocking diode to a 10A capable version rather than 5A.

Water Management PCB
Water Management PCB

Thanks to Mayhew Labs with the WebGerber image generator for the render.